TM 55-1945-205-10-40032 00 10032 00OPERATOR MAINTENANCEFLOATING CAUSEWAYLIGHT TOWERSOPERATION UNDER USUAL CONDITIONSINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 7, WP 0106 00)Life Preserver, Vest (Item 31, WP 0104 00)Gloves, Men’s and Women’s (Leather Palm) (Item 23, WP 0104 00)Goggles, Sun, Wind and Dust (safety) (Item 25, WP 0104 00)Helmet, Safety (Item 27, WP 0104 00)Personnel RequiredSeaman 88KOPERATING PROCEDURES - OPERATING PROCEDURES FOR LIGHT TOWERSSTARTING LIGHT TOWERS:,1*All personnel must wear personal flotation device, hard hat, safety shoes and gloves during FC operations and maintenance. Failure to observe these precautions could result in serious injury or death.Electrical power is present upon cranking engine. Electrical shocks could cause injury or death.127(The engine in this unit is protected with sensors for high coolant temperature and low oil pressure. Should either of these conditions occur, the engine will automatically stop causing a loss of power to all lamps (except the control panel) and receptacles. Before restarting the unit, check fuel level and engine/radiator thoroughly and correct the problem. The lamps should not be restarted for approximately fifteen (15) minutes.1.Unplug plugs from RECEPTACLES (1) and (2).