TM 55-1945-205-10-40032 00 20032 002.Position MAIN BREAKER (3) to off (down) position.3.Position LAMP switches (4), (5), (6) and (7), to off (down) position.&,21Do not use ether in conjunction with the glow plug preheat system. Failure to comply will result in engine damage.4.Turn rotary switch (8) to PRE HEAT for 5 seconds prior to starting.&,21Do not crank for more than 15 seconds without allowing starter to cool for 30 seconds. Failure to comply could result in starter damage.5.After 5 seconds, turn rotary switch (8) to START.&,21Keep side doors closed for optimum cooling of unit while running. Failure to comply could result in engine damage.6.Release rotary switch (8) after engine continues to run.7.Allow engine to run for 3 to 5 minutes before using RECEPTACLES (1) and (2) and LAMP switches (4), (5), (6) and (7).8.If engine stops unexpectedly, refer to troubleshooting procedures.9.Plug external loads into RECEPTACLES (1) and (2), as required.10. Position MAIN BREAKER (3) to the on (up) position.11. Position LAMP SWITCHES (4), (5), (6) and (7) to on (up) positions, as required.H O U R M E T E RO FFRU NSTAR TPR EH EATFUEL LEVELM AINBREAKERRECEPTACLE120 V 20ARECEPTACLE240 V 20APUSH TORESETLAM P2LAM P1LAM P4LAM P375126483