TM 55-1945-205-10-4
0057 00 5
0057 00
6.
Connect floating causeway intermediate sections along sides, as required, with guillotine
connectors. (WP 0012 00)
7.
Connect floating causeway intermediate sections end to end, as required.
a.
Rotate and pull chute bolts (2) to unlocked position.
b.
Lift guillotines (4) and (6) from flexor connector slots.
c.
Using a crowbar (3) push each flexor connector from the left end rake into corresponding pocket of right end
rake until guillotines plates (4) and (6) are aligned with the flexor connector slots.
d.
Using a sledgehammer, drive guillotine plates (4) and (6) down into flexor connector slots.
3
6
2
4