TM 55-1945-205-24-20091 00 10091 00UNIT LEVEL MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYPERSONNEL SHELTER SHORE TIE PENETRATION HINGED COVERREPLACEMENTINITIAL SETUP:ToolsTool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)Gloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00) Helmet, Safety (Brown) (Item 33, WP 0359 00)Life Preserver, Vest (Item 38, WP 0359 00)Materials/PartsCover, Assembly(81340)PN FC-621-001-128Personnel RequiredEngineer 88LREMOVE PERSONNEL SHELTER SHORE TIE PENETRATION HINGED COVERWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during RRDF operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Remove five cover hinge screws (1) securing the cover (2) to the personnel shelter exterior wall (3).2.Remove cover (2) and discard.231