TM 55-1945-205-24-20280 00 10280 00UNIT LEVEL MAINTENANCEROLL-ON/ROLL-OFF DISCHARGE FACILITYRIGID HULL INFLATABLE BOAT INFLATABLE TUBEINSPECTION AND TESTINGINITIAL SETUP:ToolsGloves, Men’s and Women’s (Leather Palm) (Item 27, WP 0359 00)Goggles, Sun, Wind and Dust (Safety) (Item 29, WP 0359 00) Helmet, Safety (Brown) (Item 33, WP 0359 00)Life Preserver, Vest (Item 38, WP 0359 00)Pump, Bravo Foot (Item 53, WP 0359 00)Pump, Foot Adaptor (Item 54, WP 0359 00)Valve, Fill (Item 84, WP 0359 00)Gage, Pressure (Item 22, WP 0359 00)Personnel RequiredEngineer 88LRHIB INFLATABLE TUBE AIR RETENTION TESTWARNINGAll personnel must wear personal flotation device, hard hat, safety shoes and gloves during RRDF operations and maintenance. Failure to observe these precautions could result in serious injury or death.1.Connect the air pump to RHIB tubes (1) at inflation points (2).2.Operate air pump until tube (1) is inflated to approximately 4.4 PSI.3.Using pressure gage, verify full tube pressure is approximately 4.4 PSI (300 mb) in both tubes (1) at all inflation points (2).22112