INSTALL RHIB INSTRUMENT WIRING HARNESS
INSTALL RHIB INSTRUMENT PANEL TOGGLE SWITCHES
TM-55-1945-205-24-2 Modular Causeway System (MCS) Roll-On/Roll-Off Discharge Facility Model (RRDF) RRDF-1 NSN 1945-01-473-2282 Manual
Page Navigation
734
735
736
737
738
739
740
741
742
743
744
TM 55-1945-205-24-2
0277 00 1
0277 00
UNIT LEVEL MAINTENANCE
ROLL-ON/ROLL-OFF DISCHARGE FACILITY
RIGID HULL INFLATABLE BOAT INSTRUMENT PANEL TOGGLE
SWITCHES
REPLACEMENT
INITIAL SETUP:
Tools
Tool Kit, General Mechanic’s (Rail and Marine) (Item 82, WP 0359 00)
Materials/Parts
Switch, Toggle
(38915)
PN E-S-20175-4
Personnel Required
Engineer 88L
References
TM 55-1945-205-10-2
Equipment Condition
RHIB Battery Negative Lead Terminal Removed. (WP 0336 00)
REMOVE RHIB INSTRUMENT PANEL TOGGLE SWITCHES
NOTE
The following procedure is typical for the removal and installation of toggle switches.
1.
Disconnect and tag electrical wiring from toggle switch (1).
2
1
3