TM 55-1945-205-24-40061 00 20061 00a.Remove the guillotine connector bar (1).{1} Remove bolt (2), nut (3) and friction plate (4).{2} Pry up on the guillotine connector bar (1) using a crowbar.WARNINGFailure to block guillotine bar in up position when removing pins and springs could result in personal injury or death. {3} Place a block of wood under the upper “lip” of the guillotine connector bar (1) after it is raised to hold it in the up position.b.Push up on the retainer located on the underside of the male connector pins (5). c.Remove male connector pins (5) from the guillotine connector lock housings (6).d.Remove deployment springs (7).e.Remove guillotine connector bar (1) from guillotine lock housings (6).46213755