TM 55-1945-205-24-4
0061 00 3
0061 00
2.
Disassemble the female guillotine connector assembly.
a.
Remove the guillotine connector bar (8).
{1} Remove bolt (9), nut (10) and friction plate (11).
{2} Pry up on the guillotine connector bar (8) using a crowbar.
b.
Remove guillotine connector bar (8) from guillotine lock housings (12).
INSPECT AND REPAIR/REPLACE COMBINATION BEACH/SEA END SECTION NON-
POWERED MODULE MALE AND FEMALE GUILLOTINE CONNECTORS
1.
Inspect male connector pin (5) for cracks, cuts or corrosion. If damaged, replace connector pin.
2.
Inspect deployment spring (7) for cracks, cuts or corrosion. If damaged, replace deployment spring.
3.
Inspect guillotine connector bars (1, 8) for cracks, cuts or corrosion. If damaged, repair or replace guillotine
connector bars (1, 8).
4.
Inspect guillotine connector male and female lock housings (6, 12) for cracks, cuts or corrosion. If damaged,
replace or replace guillotine connector lock housings (6, 12).
5.
Inspect guillotine connector assembly friction plates (4, 11) for cracks, cuts or corrosion. If damaged, replace
friction plates (4, 11).
9
10
8
12
11