TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN REPLACEMENT (Sheet 4 of 6)
12.
Using 9/16 inch socket, remove two screws (R),
bracket (U) to housing.
13.
Remove bracket (U) and pad (V).
I N S P E C T I O N AND REPAIR:
1.
Inspect bracket (U) for defects or damage. Replace or repair as necessary.
2.
Inspect condition of pad (V). If defective or deteriorating, replace.
Go on to Sheet 5