AIR CLEANER (ALUMINUM) CIRCUIT BREAKER REPLACEMENT
AIR CLEANER CENTRIFUGAL FAN GROUND LEAD REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  306    307    308    309    310  311  312    313    314    315    316  
img
. . . . .
TM 5-5420-202-20-2
AIR CLEANER CENTRIFUGAL FAN GROUND LEAD REPLACEMENT (Sheet 1 of 2)
TOOLS: 7/16 in. combination box and open end wrench
SUPPLIES:
Lockwasher (2 required)
REFERENCE:
TM 5-5420-202-10
PRELIMINARY
PROCEDURES:
Remove air cleaner centrifugal fan cover (armored,
page 7-103, aluminum, page-7-106)
Make sure MASTER BATTERY switch is OFF
(TM 5-5420-202-10)
NOTE
Remove of left or right
centrifugal fan ground lead is
the same. Left side shown.
REMOVAL:
Disconnect two connectors (A)
1.
from centrifugal fan leads (B).
2.
Using wrench, remove screw (C) and
Iockwashers (D) securing ground lead (E) to
terminal boss (F).
Remove ground lead (E).
3.
Go on to Sheet 2