TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CIRCUIT BREAKER REPLACEMENT (Sheet 1 of 1)
TOOLS: 1/2 in. socket with 1/2 in. drive
C r o s s - t i p screwdriver
REFERENCE:
NOTE
All air cleaner circuit breakers are
removed and installed the same way.
REMOVAL:
1.
Using socket, remove 10 screws (A) and Iockwashers (B) securing cover (C) to air cleaner.
2.
Using screwdriver, remove screws (D) and lockwashers (E) securing circuit breaker (F)
to cover (C).
3.
Remove circuit breaker (F).
4.
Disconnect two electrical leads (G).
INSTALLATION:
1.
Position circuit breaker (F) onto
cover (C).
Install washers (E) and screws (D) to secure
2.
circuit breaker (F) to cover (C). Use cross-
tip screwdriver and tighten screws (D).
Connect two electrical leads (G).
3.
Install cover (C) and secure with 10 screws (A)
4.
5.
Using socket, tighten screws (A).
6.
Check operation of centrifugal fans
End of Task