TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN REPLACEMENT (Sheet 6 of 6)
Position new gasket (P) on housing with
12.
sealing compound.
13.
Position cover (Q) in front of housing.
Connect lead with jumper from centrifugal
14.
fan to each circuit breaker (R).
15.
Connect one connector from power lead to
each circuit breaker. (The power lead is
the one coming from the side of the housing.)
16.
Check operation of air cleaner centrifugal
fan (TM 5-5420-202-10).
17.
Position cover (Q) to housing and install
16 screws (S), lockwashers (T), and washers (U)
to secure cover.
18.
Using 7/16 inch socket and 7/16 inch wrench,
tighten screws (S).
End of Task
7-123