TM
5-5420-202-20-2
AIR CLEANER DOOR REPAIR (Sheet 3 of 3)
INSTALLATION:
1.
Lift door assembly (A) into place on air
cleaner housing (B).
2.
Using hammer, tap three straight pins (C)
into three hinges (D).
Install three flat washers (E) onto three
3.
straight pins (C).
4.
Using hammer, tap three new cotter pins
(F) into holes in straight pins (C).
5.
Using hammer, tap cotter pins (F) around
straight pins (C) to secure washers (E) and
pins in place.
6.
Make sure door assembly (A) is in closed
position (lowered).
To prevent screws from pulling out
o f box and injuring personnel, a
m i n i m u m of 200 pounds must be
placed atop the door before install-
ing screws.
7.
Using wrench, install and tighten three
screws (G) to secure door
air cleaner housing (B).
End of Task
Change 1