TM 5-5420-202-20-2
THROTTLE CONTROL HANDLE ASSEMBLY REPLACEMENT (Sheet 2 of 2)
Using 9/16 inch socket,
3.
4.
Using 7/16 inch wrench, remove screw
(G) and lockwasher (H).
Using pliers, remove spring (J) from
5.
b r a c k e t (K).
Using hammer, tap segment (L) lightly
6.
to remove segment (L) from shaft (M).
Using pliers, remove cotter pin(N).
7.
Remove flat washer (P) and handle(Q)
8.
f r o m bracket (K).
Using hammer and punch, remove
9.
bushing(R).
10.
Using pliers, remove woodruff key (S)
from shaft (M).
C L E A N I N G AND INSPECTION:
T o prevent personal injury, wear
Dry cleaning solvent P-D-680 is toxic and flammable.
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vapors. Do not use near open flame or excessive heat. The
flash point for Type #1 Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
1.
Clean all parts using dry cleaning solvent and clean cloths.
2.
Inspect all parts for cracks, bends, wear, and other defects. Replace any defective
parts.
Go on to Sheet 3