• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Circuit Breaker Replacement (Sheet 1 of 7)
Circuit Breaker Replacement (Sheet 3 of 7)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  70    71    72    73    74  75  76    77    78    79    80  
img
.
TM 5-5420-202-20-3
MASTER CONTROL PANEL REPAIR (Sheet 34 of 73)
Circuit Breaker Replacement (Sheet 2 of 7)
REMOVAL; CIRCUIT BREAKERS (A, B, C, AND E):
Using fingers, remove two electrical connectors from rear of circuit breaker (A) by
1.
pulling out.
Using cross-tip screwdriver and wrench, remove two screws (B), lockwashers (C), and
2.
nuts (D) securing circuit breaker (A) to panel.
Remove circuit breaker (A).
3.
INSTALLATION; CIRCUIT BREAKERS (A,B,C, AND E):
Place circuit breaker (A) in position on panel.
1.
Using cross-tip screwdriver and wrench, install two screws (B), lockwashers (C), and
2.
nuts (D).
3.
Apply silicone compound to two male electrical connectors for circuit breaker (A).
Using fingers, connect two electrical connectors in rear of circuit breaker (A) by
4.
pushing in.
Go on to Sheet 3
TA249012