Circuit Breaker Replacement (Sheet 3 of 7)
Circuit Breaker Replacement (Sheet 5 of 7)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  72    73    74    75    76  77  78    79    80    81    82  
img
.
TM 5-5420-202-20-3
MASTER CONTROL PANEL REPAIR (Sheet 36 of 73)
Circuit Breaker Replacement (Sheet 4 of 7)
INSTALLATION: CIRCUIT BREAKER (D):
Place circuit breaker (A) in position on
1.
panel.
Using cross-tip screwdriver and wrench,
2.
install two screws (B), new lockwashers
(C), and nuts (D).
Apply silicone compound to two male
3.
electrical connectors for circuit breaker
(A).
Using fingers, connect two electrical
4.
connectors in rear of circuit breaker (A) by
pushing in.
Using socket, install nut (F), flatwasher
6.
(G), and lockwasher (H) securing harness
junction (E) to panel.
Go on to Sheet 5