lNTERCONNECTING BOX ASSEMBLY REPAIR (Sheet 8 of 8)
HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT (Sheet 2 of 6)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  151    152    153    154    155  156  157    158    159    160    161  
img
. . .
TM 5-5420-202-20-3
HIGH VOLTAGE IR POWER SUPPLY AND SHOCK MOUNT ASSEMBLY REPLACEMENT
(Sheet 1 of 6)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
10-152
Installation
10-155
TOOLS:
1/4 in. open end wrench
7/16 in. open end wrench
7/16 in. socket with 1/2 in. drive
7/8 in. open end wrench
1/2 in. socket with 1/2 in. drive
1 in. open end wrench
5 in. extension with 1/2 in. drive
Flat-tip screwdriver
Ratchet with 1/2 in. drive
PRELIMINARY PROCEDURE: Set MASTER BATTERY switch to OFF.
Remove commander's access plate (page 17-9)
SUPPLIES:
lockwashers (8 required)
Go on to Sheet 2