HEU SLAVE RECEPTACLE COVER REPLACEMENT
HEU SLAVE RECEPTACLE REPLACEMENT (Sheet 1 OF 2)

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -3 Page Navigation
  270    271    272    273    274  275  276    277    278    279    280  
img
. . . . .
TM 5-5420-202-20-3
HEU SLAVE RECEPTACLE GROUND STRAP REPLACEMENT
TOOLS:
9/16 in. open and closed end wrench
SUPPLIES:
Lockwashers
PRELIMINARY PROCEDURES: Disconnect three battery ground straps (page 10-268)
Remove slave receptacle cover (page 10-268.1)
REMOVAL
1. Using 9/16 inch wrench remove screw (A) and new lockwasher (B) from slave receptacle (C) and
slave receptacle ground strap (D) (CKT 50).
2. Using 9/16 inch wrench remove screw (E) and new lockwasher (F) from hull (G) and
slave receptacle ground strap (D) (CKT 49).
INSTALLATION:
1. Using 9/16 inch wrench install screw (E) and new lockwasher (F) thru slave receptacle ground strap (D)
(CKT 50) into hull (G).
2. Using 9/16 inch wrench install screw (A) and new lockwasher (P) thru slave receptacle ground strap (D)
(CKT 49) into slave receptacle (C).
3. Install slave receptacle cover (page 10-268.1).
4. Connect three battery ground straps (page 10-268).
End of Task
10-268.2