TM 5-5420-202-20-4
SMOKE GENERATOR SOLENOID OUTPUT FUEL HOSE REPLACEMENT (Sheet 2 of 2)
INSTALLATION:
Using 3/4 inch wrench, install 90-degree elbow (A) to tee (B). Adjust elbow to face
1.
engine.
Position and manually connect hose
2.
(C) to 90-degree elbow (A) and 45-degree
elbow (D).
Using 11/16 inch wrench, tighten hose
3.
(C) connectors to elbows (A) and (D).
WARNING
Do not activate smoke generator in a building or closed area or with personnel near,
CAUTION
Always be aware of wind direction and speed when using smoke generator.
4.
Run engine at 1600 rpm and activate smoke generator. Observe operation. Shut off
smoke generator. Shut down engine.
Check smoke generator lines for leaks. Correct as necessary.
5.
Install engine shroud (page 9-31).
6.
TA248774
End of Task
21-33