ARMY TM 5-5420-212-10-1
MARINE CORPS TM 08676A-10/1-1
6-17.
PICKET TYPE INSTALLATION
Use hammer to drive pickets into bank at 1 ft (0.3m) intervals along the outside edge of near bankseat bream.
Repeat this procedure for far bank bankseat beam.
6-18.
APPROACH GUY INSTALLATION
a.
General
During installation, anchorage pins will be used in end taper panels for connection of approach guy cables. This
type of anchorage is installed during construction, but can, if required, be installed once bridge is put on ground,
b.
Installation
(1)
Insert anchorage pins in anchorage pin holes in end taper panels of far bank end of bridge.
6-73