MULTIPLE FLUID PRESSURE LINE CONNECTOR REPLACEMENT - Continued
ENGINE ACCESS COVERS (RIGHT BANK) REPLACEMENT

M48A5 Tank Chassis, Transporting: For Bridge, Armored-Vehicle-Launched; Scissoring Type, Class 60 -2 Page Navigation
  146    147    148    149    150  151  152    153    154    155    156  
img
. . . .
TM 5-5420-226-20-2
MULTIPLE FLUID PRESSURE LINE CONNECTOR REPLACEMENT (Sheet 6 of 6)
CAUTION
Do not operate powerplant longer than ten minutes with
cooling fans removed. Engine speed should not exceed 750
RPM.
12.
G r o u n d hop powerplant (page 5-25).
13.
C h e c k all connections for leaks.
14.
T u r n engine off.
15.
D i s c o n n e c t ground hop equipment (page 5-25).
16.
I n s t a l l rear engine cooling fan (page 9-57).
17.
I n s t a l l powerplant (page 5-14).
End of Task