TM 55-1945-205-24-20319 00 30319 00WARNING8.Connect a 1/8 in. I.D. clear, vinyl hose (4) between the fitting and a syringe (5) filled with isopropyl alcohol.9.Press lightly on plunger of syringe (5).a.If fluid moves through fitting, there is no blockage present.b.If fluid does not move through the fitting, clean fitting with OMC Nipple Cleaning tool.10. Remove two fuel primer solenoid bracket screws (6), washers (7).11. Tag and remove white grounding wire (8).12. Remove primer solenoid bracket (9) and fuel primer solenoid (10).WARNING13. Remove three hoses (11).14. Remove the terminal screw (12).15. Tag and remove purple lead (13). 16. Test the solenoid windings by calibrating a multimeter on low ohms scale.12613101111789