TM 55-1945-205-24-2
0309 00 4
0309 00
2.
Set multimeter (1) to measure normal polarity.
3.
Connect black lead (2) to ground tab (3) and red lead (4) to primary terminal (5).
4.
Using high tension lead (9) on multimeter (1) connected to spark plug (8) terminal cap, verify reading to be
1.5 amps or 1.1 per TABLE 1.
5.
If readings do not meet the requirements as specified, replace coil (6). (WP 0310 00)
PERFORM RHIB ENGINE SURFACE LEAKAGE TEST
NOTE
Leakage is an indication of a breakdown in insulation
1.
Connect spark plug wire (8) to coil (6).
10C359-3
1
2
3
4
5
6
8
9