TM 55-1945-205-24-20309 00 5/6 blank 0309 002.Set multimeter (1) to measure normal polarity.3.Connect black lead (2) to ground tab (3) and red lead (4) to primary terminal (5).4.Using high tension lead (9) on multimeter (1), probe surface of coil (6) and spark plug wire (8).5.Verify reading to be 1.5 amps or 1.1 per chart.6.If readings do not meet the requirements as specified, replace the coil (6) or spark plug wire (8) as necessary. (WP 0310 00, WP 0308 00)7.Install RHIB engine ignition coil. (WP 0310 00)8.Install RHIB engine spark plug wires. (WP 0308 00)9.Install RHIB engine cover. (WP 0297 00)10. Install RHIB battery negative lead terminal. (WP 0336 00)END OF WORK PACKAGE12345689