TM 5-5420-202-202
POWERPLANT TESTS (GROUND HOP) (Sheet 16 of 16)
After Test Disconnect (Sheet 1 of 1)
1. Disconnect three battery ground cables (page 10-268).
2. Disconnect four electrical cable assemblies and three hose assemblies from powerplant and hull
(page 5-27).
3. Remove fabricated tachometer assembly.
4. Using socket, loosen clamp nuts that secure left
and right ground hop hose assemblies.
5. Remove ground hop hose assemblies with clamp
and filters from turbosupercharger elbow.
6. Position air cleaner hose assembly with clamp to
turbosupercharger elbow.
7. Using 7/16-inch socket with ratchet, tighten clamp
nut to secure air cleaner hose assembly to
turbosupercharger elbow.
8. Install powerplant (page 5-14).
End of Task
5-40