AIR CLEANER INTAKE AND HOSE REPLACEMENT - Continued
AIR CLEANER INTAKE ELBOW REPLACEMENT

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  250    251    252    253    254  255  256    257    258    259    260  
img
.
TM 5-5420-202-20-2
AIR CLEANER PLUG REPLACEMENT (Sheet 1 of 1)
1-1/8 in. socket with 1/2 in. drive
TOOLS:
Ratchet with 1/2 in. drive
7/16 in. combination box and open end wrench
Sealer (Item 54, Appendix D)
SUPPLIES:
NOTE
Removal of the left or right plugs
Left side shown.
are the same.
REMOVAL:
1.
Using 1-1/8 inch socket, remove two plugs (A) from air cleaner housing (C).
2.
Using 7/16 inch wrench, remove plug (B) from air cleaner housing (C).
3.
Inspect plug threads for damage. Replace as necessary.
INSTALLATION:
1. Coat threads of three plugs (A and B) with sealer and install into air cleaner housing (C).
2. Using 1-1/8 inch wrench, tighten two plugs (A).
3. Using 7/16 inch wrench, tighten plug (B).
End of Task
7-70