AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT
AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  258    259    260    261    262  263  264    265    266    267    268  
img
TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 2 of 3)
Using slip joint pliers, disconnect nut (E) from adapter (F).
5.
6.
Pull lead (G) out of adapter (F). When lead is pulled, washers (H) and (J) and gasket (K)
will also be pulled out.
7.
Remove washers (H) and (J), gasket (K), and nut (E) from lead (G).
Disconnect two leads (L) and (M) from centrifugal fan circuit breakers (N).
8.
Inspect all parts removed for defects or deterioration. Replace as necessary.
9.
Go on to Sheet 3