TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 3 of 3)
INSTALLATION:
1.
Connect two leads (A) and (B) to centrifugal
fan circuit breakers and position the
following parts on lead (C): nut (D), washers
(E) and (F), gasket (G).
Install lead (C) through adapter (H). Pull
2.
approximately 10 inches of lead out of
adapter.
Install shell (J) approximately 2 inches over
3.
end of lead (C) and install washer (K).
Pull shell (J) toward end until it is stopped
4.
by washer (K).
Push gasket (G) and washers (E) and (F)
5.
into adapter (H).
6.
Thread nut (D) onto adapter (H). Use slip
joint pliers and tighten nut.
Install air cleaner centrifugal fan
7.
Connect electrical connectors (L).
8.
Check operation of air cleaner
9.
10.
End of Task
7-79