AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN POWER LEAD REPLACEMENT
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN POWER LEAD REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  261    262    263    264    265  266  267    268    269    270    271  
img
.
TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 2 of 4)
Remove centrifugal fan nearest power lead (page 7-118).
2.
Push shell (B) back away from contact (C).
3.
Using pliers, remove washer (D) from lead (E).
4.
5.
Remove shell (B).
Using pliers and wrench loosen and back off nut (F).
6.
Pull lead (E) out of adapter (G). When lead is pulled, washers (H), (J), and gasket (K) will
7.
also be pulled out.
Remove lead (E). Remove washers (H), (J), gasket (K), and nut (F) from lead (E). Throw
8.
gasket away.
Inspect all remaining parts for defects or deterioration. Replace as necessary.
9.
Go on to Sheet 3
7-81