TM 5-5420-202-20-2
AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 1 of 3)
Slip joint pliers
TOOLS:
REFERENCE:
PRELIMINARY
PROCEDURES:
NOTE
right
Removal
of
left
or
centrifugal fan power lead is the
same. Left side shown.
REMOVAL:
1. Disconnect electrical connector (A).
2.
Push shell (B) back away from contact (C).
3.
Using slip joint pliers, remove washer
(D) from contact (C).
Remove shell (B).
4.
Go on to Sheet 2