AIR CLEANER (ARMORED) CENTRIFUGAL FAN POWER LEAD REPLACEMENT - Continued
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN POWER LEAD REPLACEMENT - Continued

Maintenance Manual For Launcher,Tank Chassis Transporting: For Bridge Armored-Vehicle-Launched: Scissoring-Type; Class 60 And 70 -2 Page Navigation
  260    261    262    263    264  265  266    267    268    269    270  
img
. . . . . .
TM 5-5420-202-20-2
AIR CLEANER (ALUMINUM) CENTRIFUGAL FAN POWER LEAD REPLACEMENT (Sheet 1 of 4)
PROCEDURE INDEX
PROCEDURE
PAGE
Removal
7-80
Installation
7-82
TOOLS: 1 in. combination box and open end wrench
Slip joint pliers
SUPPLIES:
Gasket
REFERENCE:
TM 5-5420-202-10
PRELIMINARY
PROCEDURES:
Open top deck grille doors (TM 5-5420-202-10)
Remove air cleaner centrifugal fan cover (page 7-106)
REMOVAL:
D i s c o n n e c t electrical connector (A).
1.
Go on to Sheet 2
7-80