TM 5-5420-202-20-2
TRANSMISSION MOUNTS (LEFT AND RIGHT) REPLACEMENT (Sheet 3 of 4)
NOTE
It may be necessary to turn universal to
gain access to screw (L).
8.
Using 3/4 inch socket, remove three screws
Remove bracket (C) from transmission.
9.
10.
Using hammer, remove spacer (N) from bracket
(C).
C L E A N I N G AND INSPECTION:
1.
Inspect bushing, mounts, and roller for damages.
If any parts are nicked, burred, or out of round,
replace damaged part.
T o prevent personal injury, wear
Dry cleaning solvent P-D-680 is toxic and flammable.
protective goggles and gloves and use only in a well-ventilated area. Avoid contact with skin,
eyes, and clothes and don't breathe vaports. Do not use near open flame or excessive heat. The
flash point for Type #l Dry Cleaning Solvent is 100F (38C) and for Type #2 is 138F (50C).
If you become dizzy while using cleaning solvent, get fresh air immediately and get medical aid.
If contact with eyes is made, wash your eyes with water and get medical aid immediately.
2.
Clean all parts with dry cleaning solvent and
wipe dry with rags.
INSTALLATION:
1. Position bracket (A) in vise and using
resilient mount tool assembly, install
two mounts (B) into bracket (A).
2. Using 3-1/8 inch socket and T-slide
handle, install bushing (C) into bracket
(A).
Go to Sheet 4